- FM Software 12/90 update -- Implementation notes
- ================================================
-
- Changes have been made to all of the FM Software packages since
- the June 1990 release. Note especially that extensive MIDI
- driver modifications have resulted in new command line options.
- If you used any command line options in previous releases, be
- sure to check the "Command Line Changes" section below for new
- formats before running any of the revised programs.
-
- This document covers all available packages and some sections may
- not apply to the distribution you have received.
-
-
- New MIDI Drivers
- ----------------
-
- The MIDI device interface code has been completely rewritten for
- this release. Support has been added for the Key Electronics
- MIDIator and the Creative Labs SOUND BLASTER (with MIDI adapter).
- A universal MIDI driver is employed which allows each program to
- operate with any of the supported interfaces. Default device
- selection can be overridden on the command line for systems using
- multiple interfaces. All I/O is now interrupt-driven by default,
- rather than via polled access (the previous default).
-
-
- New Programs
- ------------
-
- * Play/R -- Memory resident MIDI file player.
- See PLAYR.DOC for details if this program has been included
- with your distribution.
-
- * FM2MDX -- FM-Edit to MIDIEX bank converter.
-
- * Play/B -- Batch Play version (non-interactive).
- Replaces Play15.
-
-
- Help - All interactive programs
- -------------------------------
-
- * String search speed has been improved.
-
- * Search words can now be selected from the text using a mouse.
-
-
- Watch program
- -------------
-
- * The Alt-0 send key has been modified to ask for the send string
- each time it is pressed. This permits quicker entry of strings
- while on the Monitor screen.
-
- * The available buffer memory has been increased to approx. 80K
- bytes. The size of MIDI files loaded is now only limited by
- the amount of free memory.
-
-
- Play program
- ------------
-
- * Play list support has been added for continuous, automatic
- play.
-
- * Function keys and mouse selectors have been altered due to new
- functions associated with play lists. Check the help screen
- for the new definitions.
-
- * Files are now sorted alphabetically in the file list display,
- and play lists can be created by selecting files from that
- display.
-
- * There is now a meter display mode available (Alt-F6) which
- shows song length and position in measures and beats. Time
- signature is also shown in this mode. The time display is now
- more consistent when advancing.
-
- * A delay between songs in a play list can be specified using the
- -w option on the command line.
-
- * MIDI file size is now only limited by the amount of available
- memory.
-
-
- File extensions
- ---------------
-
- * Programs which read MIDI files will now check for any of the
- following extensions if none is specified: .mff, .mid, .std,
- .smf.
-
- * The default extension (.mff) for wildcard directories searches
- can be changed via the mff environment variable.
- Ex: set mff=mid
-
-
- Command Line Changes
- --------------------
-
- All programs which do MIDI input/output now use the "-d" option
- to select the active device (if more than one is present):
-
- -dmfc selects IBM Music Feature
- -dmpu selects MPU-401 compatible
- -dmidiator selects MIDIator
- -dsbmidi selects Sound Blaster MIDI
-
- (The first 3 letters of the device name are sufficient.)
-
- Optional IRQ and I/O port address information can be added
- following the device id if necessary:
-
- -dxxx:<irq>:<ioaddr>
-
- For example, to define an MPU-compatible interface using IRQ
- 5 and I/O address 332 (hex), use:
-
- -dMPU:5:332
-
- If only the I/O address is required but the default IRQ is
- alright, use -dMPU::332.
-
- Other new options include "-i" which will try to determine the
- IRQ in use automatically (MPU and MFC only), "-v" which lists
- the type of interface actually selected before starting, and
- "-s" which doubles the size of the MIDI input buffer.
-
- Command line options (those beginning with "-") may be set
- permanently by including DOS environment variable definitions in
- your autoexec.bat file. Use the variables opt1, opt2, opt3, and
- so on. Be to include the "-" character before the option letter.
- For example, "set opt1=-dmpu:5:332". This has the same effect as
- including the -d option described above on each command.
-
-
- Device restrictions
- -------------------
-
- MIDIator
-
- With the current drivers, the MIDIator is not automatically
- detected as are the other device types. The -dmid option must
- always be specified on any of the program command lines to
- utilize this device. This can be set by default by defining an
- environment variable before use (usually in the autoexec.bat
- file):
- set opt1=-dmid
-
-
- SOUND BLASTER
-
- Technically, the SOUND BLASTER uses a half-duplex MIDI
- implementation, meaning that it cannot simultaneously send and
- receive MIDI data. The MIDI driver "simulates" full-duplex
- operation by rapidly switching between input and output modes.
- This is not 100% effective, however, and some input data may
- be lost during "thru" operations. In particular, the
- thru/patchbay operations in the Watch program may not prove
- useful, depending on the amount of data being received. Thru
- operations are disabled entirely if not using interrupt-driven
- mode (i.e., -dsbm:0 is specified on the command line indicating
- no interrupt). Because of the i/o restriction, the FM-Tune
- program will also not operate correctly and so is not supported
- for use with the SOUND BLASTER.
-
-
- Questions
- ---------
-
- Questions or problems regarding this software should be addressed to:
-
- Kevin Weiner
- FM Software
- 1413 Spring St.
- Bethlehem, PA 18018
-
- (215) 865-7956
-
- CompuServe: 72416,2465